Bash Medical
  • Giriş/Entry
  • Ana Sayfa
  • ürünler
  • iletişim
  • HOME
  • PRODUCTS
  • Contact Us
  • tr MCL60
  • MCL60
  • tr GPP-100
  • GPP-100
  • tr Omlipo
  • tr KU-2800
  • tr KU-F40
  • tr KU-F600
  • tr KU-U200
  • tr KU-600
  • Daha fazlası
    • Giriş/Entry
    • Ana Sayfa
    • ürünler
    • iletişim
    • HOME
    • PRODUCTS
    • Contact Us
    • tr MCL60
    • MCL60
    • tr GPP-100
    • GPP-100
    • tr Omlipo
    • tr KU-2800
    • tr KU-F40
    • tr KU-F600
    • tr KU-U200
    • tr KU-600
  • Giriş Yap
  • Hesap Oluştur

  • Hesabım
  • Şu kullanıcı olarak giriş yapıldı:

  • filler@godaddy.com


  • Hesabım
  • Oturumu kapat

Bash Medical

Şu kullanıcı olarak giriş yapıldı:

filler@godaddy.com

  • Giriş/Entry
  • Ana Sayfa
  • ürünler
  • iletişim
  • HOME
  • PRODUCTS
  • Contact Us
  • tr MCL60
  • MCL60
  • tr GPP-100
  • GPP-100
  • tr Omlipo
  • tr KU-2800
  • tr KU-F40
  • tr KU-F600
  • tr KU-U200
  • tr KU-600

Hesap


  • Hesabım
  • Oturumu kapat


  • Giriş Yap
  • Hesabım

ThromBash XRS

Safe. Intelligent. Reliable.

  • ThromBash XRS is a fully-automated in vitro coagulation analyzer which delivers high quality results and meets the increasing requirements of modern high-volume labs.
  • Positive Reagent and Sample identification: Reagent batch- and bottle specific ID guarantees safe and traceable reagent management with ThromBash reagents or third-party reagent. The sample handling with cap piercing technology for variable primary receptacles, in a patented sample rack transport system with positive sample identification, provides high user convenience.
  • Productivity and Efficiency: Continuous loading and the high on-board capacity of samples, reagents and consumables ensure an uninterrupted workflow and a long walk-away-time. By using two independent samplers for plasma and reagents, combined with an 8-channel measuring system, the analyzer achieves a throughput of 320 tests/h.
  • Practicality and Reliability: Just a few minutes of daily and weekly maintenance are enough to keep the system up and running. That means lower instrument downtime, less lab personnel expenditure of time and higher processing capacity for patient samples. The XRS, like all ThromBash systems, is well known for reliability with very low operating and maintenance costs.

 

ThromBash XRC

Solid. Convenient. Reliable.

  • ThromBash XRC is a fully-automated in vitro coagulation analyzer which delivers high quality results and meets the demands of mid-volume labs with easy, intuitive usage.
  • Flexibility and Functionality: Working with the sample rotor ensures maximum achievable flexibility. The sample handling with cap piercing technology for variable primary receptacles provides high user convenience. The positive sample identification, with scanning the barcode directly before sample withdrawal, makes this system absolutely safe.
  • Productivity and Efficiency: Continuous loading and the on-board capacity of samples, reagents and consumables ensure an uninterrupted workflow and a long walk-away-time. With a maximum throughput of 160 tests/h, the analyzer is suitable for all low and mid-volume labs.
  • Practicality and Reliability: Just a few minutes of daily and weekly maintenance are enough to keep the system up and running. That means lower instrument downtime, less lab personnel expenditure of time and higher processing capacity for patient samples. The XRC, like all ThromBash systems, is well known for reliability with very low operating and maintenance costs.

 

ThromBash XRC

Proven. Tough. Reliable.

  • ThromBash X is a fully-automated in vitro coagulation analyzer which delivers high quality results with the reliability of the established  ThromBash series for low and mid-volume labs.
  • Precision and Correctness: Normal or interference samples are monitored by the system photometer which automatically changes both light intensity and wavelength. This feature, combined with a rotating steel ball amplifies the measuring signal, secures precision and correctness of each result. Results out of specification are automatically repeated; possibly with a different dilution or reflex test.
  • Productivity and Efficiency: Continuous loading and the on-board capacity of samples, reagents and consumables ensure an uninterrupted workflow and a long walk-away-time. With a maximum throughput of 160 tests/h, the analyzer is suitable for all low and mid-volume labs.
  • Practicality and Reliability: Just a few minutes of daily and weekly maintenance are enough to keep the system up and running. That means lower instrument downtime, less lab personnel expenditure of time and higher processing capacity for patient samples. Compact X, like all ThromBash systems, is well known for reliability with very low operating and maintenance costs.

 

ThromBash Timer 1 - 2 - 4

Easy. Innovative. Reliable.

  • ThromBash Timer is a semi-automated opto-mechanical in vitro coagulation analyzer which delivers high quality results and meets the demands of standardization in labs.
  • Measuring system: The opto-mechanical measuring system is a combination of a light source which adjusts to the samples turbidity and a rotating steel ball. Different parameters lead to clot detection. The light signal decreases due to a strong clot. Clots are centered by the rotation of the ball and this amplifies the measuring signal. Due to the centering of weak clots, the remaining fibrinogen is rapidly removed and guarantees a strong signal.
  • Flexibility: After switching on the system automatically checks all important functions and is ready for use in a short time.
  • Standardized workflow: With a definable incubation time for the test, as well as acoustic and visible signal when finished, incubating sample and reagent is easy. The system starts the measurement automatically upon start-reagent addition by using a standard laboratory pipette.

 

ThromBash Reagents

Simple. Stable. Reliable.

The ThromBash reagents are characterized by simplicity and high quality with long stability time. As complete solution in combination with ThromBash devices and validated applications we guarantee reliable high quality coagulation results in precision and accuracy.

ThromBash PT - Low ISI

  • Lyophilized Thromboplastin of rabbit cerebral tissue
  • Reconstitution diluent included in the set.
  • Ready to use right after reconstitution.
  • High ISI: 1.1 to 1.3
  • No interferences with: Triglycerides <731 mg/dL, Bilirubin <228 µmol/L, Hemoglobin <258 µmol/L, Low molecular weight Heparin <0.114 IU, Unfractionated Heparin <0.038 IU
  • Stability (reconstituted): 7 days at 2–8°C
    OBS: 72h at 18–22°C & 8h at 37°C

ThromBash PT

  • Lyophilized Thromboplastin of rabbit cerebral tissue
  • Reconstitution diluent included in the set.
  • Ready to use right after reconstitution.
  • High ISI: 1.5 to 1.7
  • No interferences with: Triglycerides <774 mg/dL, Bilirubin <162 µmol/L, Hemoglobin <258 µmol/L, Low molecular weight Heparin <0.114 IU
  • Stability (reconstituted): 5 days at 2–8°C
    OBS: 24h at 18–22°C & 8h at 37°C

ThromBash aPTT K

  • Lyophilized Cephalin (rabbit cerebral tissues) and activator Kaolin
  • Calcium chloride solution included in the set.
  • Ready to use right after reconstitution.
  • The use of Kaolin minimizes the reading time and optimizes the optical detection.
  • Insensitive to lupus anticoagulant
  • No interferences with: Triglycerides <731 mg/dL, Bilirubin <133 µmol/L, Hemoglobin <261 µmol/L
  • Stability (reconstituted): 30 days at 2–8°C
    OBS: 240h at 18–22°C

ThromBash aPTT SIL

  • Lyophilized Cephalin (rabbit cerebral tissues) and activator Kaolin
  • Calcium chloride solution included in the set.
  • Ready to use right after reconstitution.
  • Insensitive to lupus anticoagulant
  • No interferences with: Triglycerides <731 mg/dL, Bilirubin <124 µmol/L, Hemoglobin <261 µmol/L
  • Stability (reconstituted): 30 days at 2–8°C
    OBS: 144h at 18–22°C

ThromBash Fibrinogen

  • Lyophilized Thrombin of animal origin
  • Dilution buffer included in the set.
  • Ready to use right after reconstitution.
  • The ingredient Kaolin optimizes the optical detection.
  • Linearity Range: 100 to 871 mg/dL
  • No interferences with: Triglycerides <731 mg/dL, Bilirubin <496 µmol/L, Hemoglobin <261 µmol/L, Low molecular weight Heparin <2.00 IU, Unfractionated Heparin <1.66 IU
  • Stability (reconstituted): 7 days at 2–8°C
    OBS: 24h at 18–22°C

ThromBash TT

  • Lyophilized calcified thrombin of bovine origin
  • Approx. 1.5 NIH/mL thrombin after reconstitution
  • Thrombin Time
  • No interferences with: Triglycerides <900 mg/dL, Bilirubin <43 µmol/L, Hemoglobin <246 µmol/L
  • Stability (reconstituted): 7 days at 2–8°C
    OBS: 48h at 18–22°C

ThromBash D-Dimer

  • Ready to use latex reagent containing polystyrene particles coated with monoclonal antibodies.
  • Dilution buffer and Calibrator are included in the set.
  • Wavelengths 400 – 800 nm
  • Measuring range 100 – 3200 ng/mL
  • Cut-off 200 ng/mL
  • Test with a sensitivity of 95 %, specificity of 64 % and negative predictive value (NPV) of 98 %
  • No interferences with: Triglycerides <290 mg/dL, Bilirubin <855 µmol/L, Hemoglobin <1,86 mmol/L
  • Stability (reconstituted): 8 weeks at 2–8°C
    OBS: 120h at 18–22°C

ThromBash Factor Deficient Plasmas

  • Deficient plasma of human origin intended for in vitro determination of Factor II, V, VII, X and Factor VIII, IX, XI, XII activity in citrated human plasma.
  • Lyophilized plasma of human origin free of the specific factor by selective immune adsorption.
  • Additional needed diluent BE Owren Buffer.
  • Stability (reconstituted): 8h at 2–8°C
    OBS: 4h at 18–22°C

ThromBash PT Calibration Set

  • Lyophilized citrated plasma of human origin
  • Three different levels of calibration plasma for Prothrombin Time (%, INR)
  • ThromBash PT Calibration Set values are traceable to WHO INTERNATIONAL STANDARD THROMBOPLASTIN, RABBIT, PLAIN (RBT) from NIBSC
  • Stability (reconstituted): 4h at 2–25°C

ThromBash Calibration Reference Plasma

  • Lyophilized citrated plasma of human origin
  • Calibration plasma for Fibrinogen and Coagulation Factors
  • ThromBash Calibration Reference values are determined against its secondary standards of the corresponding primary International Standard for relevant parameters: SSC/ISTH Secondary Coagulation Standard NIBSC code: SSCLOT4
  • Stability (reconstituted): 4h at 2–25°C

ThromBash Control  Plasma Level 1 & 2

  • Lyophilized citrated plasma of human origin
  • Control plasma for Prothrombin Time (PT %, INR, sec.), Activated Partial Thromboplastin Time (APTT sec.), Fibrinogen (mg/dL), Thrombin Time, Factor II (%), Factor V (%), Factor VII (%), Factor VIII (%), Factor IX (%), Factor X (%), Factor XI (%) and Factor XII (%)
  • Stability (reconstituted): 10h at 2–25°C
    5 days –20°C

ThromBash Control Plasma Low & Normal & High

  • Lyophilized citrated plasma of human origin
  • Control plasma for Prothrombin Time (PT %, INR, sec.), Activated Partial Thromboplastin Time (APTT sec.), Fibrinogen (mg/dL), Thrombin Time, 
  • Stability (reconstituted): 10h at 2–25°C
    5 days –20°C

ThromBash D-Dimer Control 1 & 2

  • Lyophilized plasma of human origin enriched with D-Dimer
  • Control plasma for immunoturbidimetric determination of D-Dimer (ng/mL DDU)
  • Stability (reconstituted): 7 days  at 2–25°C
    24h at  20–25°C

ThromBash Clean

  • Cleaning solution, acid based
  • Ready to use reagent suitable for all ThromBash systems
  • Storage at 2 – 25 °C
  • Stability (once opened)
    OBS: 6 days at 18–22°C

ThromBash Clean Pro

  • Cleaning solution, Sodium hydroxide solution (NaOH), 1 mol/L
  • Ready to use reagent suitable for all ThromBash automated systems
  • Storage at 2 – 25 °C
  • Stability (once opened)
    OBS: 6 days at 18–22°C
  • Caped with silicone cap for ThromBash XRA 28 days on board

ThromBash Owren Koller Buffer

  • Dilution buffer for determination of Factor II, Factor V, Factor VII, Factor VIII, Factor IX, Factor X, Factor XI and Factor XII
  • Stability (once opened):
    OBS 6 days at 15–25°C 

ThromBash Fibrinogen Buffer

 

  • Dilution buffer for determination of Fibrinogen on semi-automated systems (plasma dilutions 950 µl buffer on ThromBash Timer).
  • Same buffer as enclosed in the ThromBash Fibrinogen set.
  • Stability (once opened):
    OBS 6 days at 15–25°C 

ThromBash Kaolin

  • Additive reagent for Fibrinogen tests with third-party reagents
  • Kaolin optimizes the optical detection
  • Kaolin 3.0 g/l for fully automated systems, ThromBash
  • Kaolin 0.5 g/l for semi-automated systems, ThromBash Timer
  • Ready to use reagent
  • Stability: Stored at 2-8°C, until the expiry date stated on the label